Pharmatec Pure Steam Generators utilize an efficient evaporation column identical to the Pharmatec Multiple-Effect Water Still, thereby providing the highest quality Pure Steam. When condensed, the pure steam exceeds the requirements of the latest US Pharmacopoeia for Water-for-Injection. Each unit is produced to comply with the US FDA’s current Good Manufacturing Practices and is manufactured in accordance to ISO 9001 quality standards.
MODEL PURE STEAM Quantity of pure steam based on heating steam pressure
|
psig
|
bar
|
116 psig
lbs/hr
|
8 bar
kg/hr
|
87 psig
lbs/hr
|
6 bar
kg/hr
|
58 psig
lbs/hr
|
4 bar
kg/hr
|
|
|---|---|---|---|---|---|---|---|---|
|
PSG 50 E |
30 | 2 | 110 | 50 | * | * | * | * |
| PSG 100 E | 30 | 2 | 220 | 220 | * | * | * | * |
|
PSG 200 E |
30 | 2 | 440 | 200 | * | * | * | * |
|
PSG 200 |
30 | 2 | 231 | 105 | 176 | 80 | 99 | 45 |
|
|
45 | 3 | 176 | 80 | 110 | 50 | ||
|
PSG 300 |
30 | 2 | 902 | 410 | 715 | 325 | 418 | 190 |
|
|
45 | 3 |
726
|
330 | 484 | 220 | ||
|
PSG 350 |
30 | 2 |
1232
|
560 | 1001 | 455 | 583 | 265 |
|
|
45 | 3 |
1012
|
460 | 682 | 310 | ||
|
PSG 400 |
30 | 2 | 1606 | 730 | 1430 | 650 | 825 | 375 |
|
|
45 | 3 | 1452 | 660 | 968 | 440 | ||
|
PSG 500 |
30 | 2 | 2458 | 1117 | 1878 | 853 | 1056 | 1056 |
|
|
45 | 3 | 1958 | 890 | 1316 | 598 | ||
|
PSG 600 |
30 | 2 | 4356 | 1980 | 2904 | 1320 | 2486 | 1130 |
|
|
45 | 3 | 3619 | 1645 | 2596 | 1180 | ||
|
PSG 650 |
30 | 2 | 6270 | 2850 | 4620 | 2100 | 3410 | 1550 |
|
|
45 | 3 | 4840 | 2200 | 3630 | 1650 | ||
|
PSG 700 |
30 | 2 | 8360 | 3800 | 5830 | 2650 | 4290 | 1950 |
|
|
45 | 3 | 7150 | 3250 | 4400 | 2000 | ||
|
PSG 800 |
30 | 2 | 10868 | 4940 | 8289 | 3768 | 4635 | 2107 |
|
|
45 | 3 | 8642 | 3928 | 5786 | 2630 |
* Electrically heated
Pure Steam Pressure Control
Pharmatec Pure Steam Generators provide extremely tight control of the pure steam pressure with ±1.5 psig (0.1 bar). A pressure transducer monitors the pure steam pressure and automatically varies the heating steam pressure to maintain the operator-selected set point. Feed water is controlled by a modulating control valve. This precise control of the pure steam eliminates the need for costly sanitary pressure reducing valves in the pure steam header.
Tension-Free Evaporator Design
The Pharmatec Pure Steam Generator utilizes an evaporator design that allows the evaporator tube bundle to be totally immersed in feed water. The shell side of the evaporator contains the heating steam. The feed water is always present whenever heating steam is applied to the evaporator. As a result, when heating or cooling occurs in the pure steam generator, the shell and tubes will expand or contract at the same rate. This eliminates tension to the tubes, shell, welds, and reduces stress corrosion. The feed water immersed tubes allow for steady generated steam flow upward in the tubes, which greatly reduces
the scaling effect prone to dry falling film. As a result of this
safe design, Pharmatec evaporators are warranted for a full two years.