The Ecocell line of ovens with natural circulation air flow, offers a noiseless and vibration-free solution for drying and heating needs. The low velocity air flow ensures safe processing of lightweight powders or other products that can be disturbed by higher air flow.
Features include:
| Specifications | Model | 55 | 111 | 222 | 404 | 707 | ||
| Interior dimensions | volume | ft3 | 1.94 | 3.92 | 7.84 | 14.27 | 24.97 | |
| liters | 55 | 111 | 222 | 404 | 707 | |||
|
Interior made of AISI 316L |
width | inches | 15.75 | 21.26 | 21.26 | 21.26 | 37 | |
| stainless steel | mm | 400 | 540 | 540 | 540 | 940 | ||
| depth | inches | 15.35 | 15.35 | 21.26 | 21.26 | 21.26 | ||
| mm | 390 | 390 | 540 | 540 | 540 | |||
| height | inches | 13.78 | 20.87 | 29.92 | 55.51 | 55.51 | ||
| mm | 350 | 530 | 760 | 1410 | 1410 | |||
| Shelves |
number of shelf guides |
max number | 4 | 7 | 10 | 19 | 19 | |
|
in chamber side walls |
shelves incl. | 2 | 2 | 2 | 2 | 2 | ||
|
Maximum weight of load(*) |
Per tray | Max lbs | 44 | 44 | 66 | 66 | 110 | |
|
Max. inside oven |
Max lbs | 110 | 110 | 154 | 220 | 286 | ||
| Door | No. | 1 | 1 | 1 | 1 | 2 | ||
| External dimensions | width | inches | 24.41 | 29.92 | 29.92 | 29.92 | 45.67 | |
| (including door and handle) | mm | 620 | 760 | 760 | 760 | 1160 | ||
| depth | inches | 25.2 | 25.2 | 31.1 | 31.1 | 31.1 | ||
| mm | 640 | 640 | 790 | 790 | 790 | |||
| ` | height | inches | 26.77 | 33.86 | 42.91 | 75.2 | 75.2 | |
| mm | 680 | 860 | 1090 | 1910 | 1910 | |||
| Shipping dimensions | width | inches | 27.95 | 33.46 | 33.46 | 33.46 | 49.21 | |
| mm | 710 | 850 | 850 | 850 | 1250 | |||
| depth | inches | 28.35 | 28.7 | 33.86 | 33.86 | 35.83 | ||
| mm | 720 | |||||||
|
height (incl. pallet) |
inches | 35.43 | 42.52 | 52 | 84.65 | 84.65 | ||
| mm | 900 | 1080 | 1320 | 2150 | 2150 | |||
| Weight | net | lbs | 121.25 | 165 | 221 | 331 | 474 | |
| kg | 55 | 75 | 100 | 150 | 215 | |||
| gross | lbs | 134.5 | 185 | 258 | 364 | 514 | ||
| kg | 61 | 84 | 117 | 165 | 233 | |||
| Electric parameters | max input | kW | 1.2 | 1.8 | 1.8 | 3.6 | 4.5 | |
| standby mode | W | 5 | 5 | 5 | 5 | 5 | ||
| current | A | 5.2 | 7.8 | 7.8 |
3.9;3.9 7.8 |
3.9;7.8 7.8 |
||
| 10.4 | 15.7 | 15.7 |
10.4;6.8; 10.4 |
10.5;13.5 10.5 |
||||
|
20.8;13.6 20.8 |
21;27;21 | |||||||
| nominal voltage | V | 115/230 | 115/230 | 115/230 | 3x400 | 3x400 | ||
| 3x230 | 3x230 | |||||||
| Working temperature (regular start) |
from 5°C over ambient temp. to °C |
|||||||
| 250 | 250 | 250 | 250 | 250 | ||||
|
Temp. deviations acc. to DIN 880 T2 from working temp. |
Approx.±% of set temp. |
|||||||
| Space Accuracy | 2 | 2 | 2 | 2.5 | 3.5 | |||
|
Pressure 5-10 mbar** all shelves |
||||||||
| Time Accuracy | ±° C | 0.3 | ≤ 0.8 | ≤ 0.8 | ≤ 1 | ≤ 1 | ||
|
Time required to reach 250° C with closed air flap and 230V power |
Minutes | |||||||
| 59 | 60 | 99 | 85 | 95 | ||||
| Heat Emissions | W | 590 | 760 | 990 | 1940 | 2550 | ||
| Air Exhange speed at 150°C | Hour | 8 | 12 | 5 | 4 | 3 | ||
| * Approx. 50% of the tray area can be filled in a way a uniform air circulation is enabled inside the chamber. Note: All technical data are related to 22° C ambient temperature and +/- 10% voltage swing (if not specified). Changes in design and make are reserved. | ||||||||
STANDARD LINE CONTROL SYSTEM
The microprocessor based control system automatically controls all phases of the process. Temperature control is based on “fuzzy logic” to ensure the fastest possible cycle without overshoot of the temperature set point.
Features include:
COMFORT LINE CONTROL SYSTEM
The microprocessor based control system has all the features of the Standard Line Control System with the addition of the following:
Features include:
Ecocell Available Options